Review





Similar Products

94
Bio-Rad yeast cellswas performedusing thechef yeast genomic dna plug kit
Yeast Cellswas Performedusing Thechef Yeast Genomic Dna Plug Kit, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plug/CHEF+Yeast+Genomic+DNA+Plug+Kit/pm42823428-251-8-18
Average 94 stars, based on 1 article reviews
yeast cellswas performedusing thechef yeast genomic dna plug kit - by Bioz Stars, 2026-10
94/100 stars
  Buy from Supplier

99
Oxford Instruments imaris colocalization finder plug in
Imaris Colocalization Finder Plug In, supplied by Oxford Instruments, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plug/Imaris/pm42815651-125-6-6
Average 99 stars, based on 1 article reviews
imaris colocalization finder plug in - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

96
Bio-Rad precision plus protein standard
Precision Plus Protein Standard, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plug/Precision+Plus+Protein+Standard+Plugs/pm42815390-77-0-4
Average 96 stars, based on 1 article reviews
precision plus protein standard - by Bioz Stars, 2026-10
96/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer ii plug
Amplatzer Ii Plug, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plug/amplatzer+ii+plug+vascular/pmc13264216-36-14-17
Average 86 stars, based on 1 article reviews
amplatzer ii plug - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

93
CELLTREAT Scientific plug seal tissue culture flasks
Plug Seal Tissue Culture Flasks, supplied by CELLTREAT Scientific, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plug/Tissue+Culture+Treated+Flasks/bio_rxiv__64898__2026__08__18__745565-214-37-41
Average 93 stars, based on 1 article reviews
plug seal tissue culture flasks - by Bioz Stars, 2026-10
93/100 stars
  Buy from Supplier

86
St Jude Medical amplatzer vascular plug
Amplatzer Vascular Plug, supplied by St Jude Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plug/amplatzer+ii+plug+vascular/pmc13266117-24-9-12
Average 86 stars, based on 1 article reviews
amplatzer vascular plug - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

96
Bio-Rad size standard precision plus protein
Size Standard Precision Plus Protein, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plug/Precision+Plus+Protein+Standard+Plugs/10__1016_slash_j__foodhyd__2026__113258-101-0-5
Average 96 stars, based on 1 article reviews
size standard precision plus protein - by Bioz Stars, 2026-10
96/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer vascular plug
Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm <t>Amplatzer</t> Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .
Amplatzer Vascular Plug, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plug/amplatzer+ii+plug+vascular/pmc13054279-34-3-7
Average 86 stars, based on 1 article reviews
amplatzer vascular plug - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer plugs
Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm <t>Amplatzer</t> Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .
Amplatzer Plugs, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plug/amplatzer+ii+plug+vascular/pmc12995491-23-20-23
Average 86 stars, based on 1 article reviews
amplatzer plugs - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Biosentry Inc biosentry plug
Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm <t>Amplatzer</t> Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .
Biosentry Plug, supplied by Biosentry Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plug/biosentry+plug/pmc13022666-82-13-13
Average 86 stars, based on 1 article reviews
biosentry plug - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

Image Search Results


Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm Amplatzer Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

Article Title: Black candy-plug technique for a large false lumen in a patient with complicated type B aortic dissection

doi: 10.1016/j.jvscit.2026.102212

Figure Lengend Snippet: Under intravascular ultrasound (IVUS) guidance, the dissection flap was punctured from the true lumen into the false lumen (FL) approximately 2 cm distal to the caudal end of the thoracic stent graft, and a Radifocus guidewire was advanced into the FL (A) . The fenestration was then dilated using an 8 mm × 4 cm balloon catheter (B) . The modified Excluder aortic extender (Ex-cuff) was deployed at the distal level of the thoracic stent graft (C) . Subsequently, a 16-mm Amplatzer Vascular Plug I, preloaded with a 2.2F microcatheter was deployed at the waist of the modified Ex-cuff (D) . The microcatheter was then withdrawn into the plug, and four detachable coils were placed within the plug (E and F) . Angiography revealed persistent perigraft leakage around the Ex-cuff (G) . Therefore, 33% n-butyl-2-cyanoacrylate (NBCA) was slowly injected, achieving complete occlusion (H) ( arrowhead , coil-in-plug; arrow , NBCA-Lipiodol). Completion angiography confirmed complete elimination of FL perfusion in the thoracic aortic segment (I) .

Article Snippet: Subsequently, a 16-mm Amplatzer Vascular Plug I (Abbott), preloaded with a 2.2F-microcatheter (Coiling Support, HI-LEX Co) was delivered through a 6F guiding catheter (Destination; Terumo Medical Co) and deployed at the waist of the modified Ex-cuff ( , D ).

Techniques: Dissection, Modification, Injection